The installation of mineral-surfaced roll roofing shall comply with this section.
The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. Mineral-surfaced roll roofing shall not be applied on roof. The installation of slate shingles shall comply with the provisions of this section.
2018 International Residential Code (Irc) | Icc Digital Codes 2018 IRC. The installation of slate shingles shall comply with the provisions of this section. Asphalt shingles shall comply with ASTM D3462. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). 201 0 obj
<>
endobj
Brace gable end walls taller than 48. inches in height to resist wind forces by installing a framing assembly at each gable wall stud. The installation of wood shakes shall comply with the provisions of this section. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions.
26 gage [0.019 inch (0.5 mm)] corrosion-resistant sheet metal and shall extend not less than 11 inches (279 mm) from the centerline each way. Mineral-surfaced roll roofing shall conform to ASTM D3909 or ASTM D6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. Liquid-applied roofing shall be installed in accordance with this chapter and the, Where required, an ice barrier shall comply with, In areas where there has been a history of ice forming along the eaves causing a backup of water, as designated in, The use of above-deck thermal insulation shall be permitted provided that such insulation is covered with an. Minimum headlap for slate shingles shall be in accordance with Table R905.6.5. Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, ASTM D6162; D6163; D6164; D6222; D6223; D6298, As an alternative, self-adhering polymer-modified bitumen, As an alternative, a minimum 4-inch-wide (102 mm) strip of self-adhering polymer-modified bitumen membrane complying with ASTM D1970, installed in accordance with the, The cap nail shank shall be not less than 0.083 inch (2.11 mm) for ring shank cap nails and 0.091 inch (2.31 mm) for smooth shank cap nails. The International Residential Code (IRC) and the Residential Edition of the Florida Building Code (FBC) both refer to Table R503.2.1.1(1) of the APA Engineered Wood Construction Guide for specs. Sheathing Requirements R905.2.1 Asphalt shingles shall be fastened to solidly sheathed decks. A base sheet that complies with the requirements of Section 1507.11.2 of the. R905.2.1 Sheathing requirements. In areas where the average daily temperature in January is 25F (-4C) or less, Wood shingles shall be installed in accordance with this chapter and the manufacturer's instructions. The bottom layer shall be 18 inches (457 mm) and the top layer not less than 36 inches (914 mm) wide. Base flashing against a vertical sidewall shall be continuous or step flashing and shall be not less than 4 inches (102 mm) in height and 4 inches (102 mm) in width and shall direct water away from the vertical sidewall onto the roof or into the gutter.
2021 International Residential Code (Irc) | Icc Digital Codes Install drip edges at eaves and rakes. Same as Maximum Ultimate Design Wind Speed, Preservative-treated shakes and shingles of, Fire-retardant-treated shakes and shingles of, Preservative-treated tapersawn shakes of Southern pine treated in accordance with AWPA Standard U1 (Commodity Specification A, Special Requirement 4.6), Forest Products Laboratory of the Texas Forest Services, Preservative-treated tapersawn shakes of Southern Yellow Pine, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum, Asphalt shingles shall have the minimum number of fasteners required by the manufacturer's, Where required, ice barriers shall comply with, Flashing for asphalt shingles shall comply with this section and the asphalt shingle manufacturer's, Base and cap flashing shall be installed in accordance with manufacturer's instructions. Paint systems in accordance with ASTM A 755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A 792, ASTM A 875, ASTM A 463, or ASTM A 653. Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. Interpretation #: CEB-2018-10-2005-IRC-R905.2.1 Building or Fire Safety Law Interpreted 675 IAC 14-4.3, the 2005 Indiana Residential Code. Thermoplastic single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Liquid-applied roofing shall comply with ASTM C836, C957, D1227, D3468, D6083, D6694 or D6947. ASTM B209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum thickness for pressformed shingles. Liquid-applied roofing shall have a design. Flashing for asphalt shingles shall comply with this section. Roof valley flashing shall be not less than No. For open valleys (valley lining exposed) lined with metal, the valley lining shall be not less than 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table R905.2.8.2. Table R806.5 of the 2018 IRC lists the thermal insulation requirements for each assembly. Asphalt shingle packaging shall bear a, Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum, Asphalt shingles shall have the minimum number of fasteners required by the manufacturer, but not less than four fasteners per strip shingle or two fasteners per individual shingle. SECTION R803 ROOF SHEATHING. Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. or less. Section R804 Cold-Formed Steel Roof Framing Section R806 Roof Ventilation Section R807 Attic Access Chapter 9 Roof Assemblies General Re-Roof Requirements .
PDF Residential Roof Sheathing and Shear Walls or Braced Wall Panels Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. Thermoplastic single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Base flashing shall be of either corrosion-resistant metal of minimum nominal 0.019-inch (0.5 mm) thickness or mineral-surfaced roll roofing weighing not less than 77 pounds per 100 square feet (4 kg/m. SECTION R804 COLD-FORMED STEEL ROOF FRAMING. The installation of mineral-surfaced roll roofing shall comply with this section. ASTM B209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum thickness for pressformed shingles. A base sheet that complies with the requirements of. Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, ASTM D6162; D6163; D6164; D6222; D6223; D6298, As an alternative, self-adhering polymer-modified bitumen, As an alternative, a minimum 4-inch-wide (102 mm) strip of self-adhering polymer-modified bitumen membrane complying with ASTM D1970, installed in accordance with the, The cap nail shank shall be not less than 0.083 inch (2.11 mm) for ring shank cap nails and 0.091 inch (2.31 mm) for smooth shank cap nails. Liquid-applied roofing shall have a design. Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. For SI: 1 inch = 25.4 mm, 1 mile per hour = 0.447 m/s. %%EOF
Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with, Flashing against a vertical front wall, as well as soil, A drip edge shall be provided at eaves and rake edges of shingle roofs.
2018 International Residential Code (Irc) | Icc Digital Codes Above-deck thermal insulation board shall comply with the standards in Table 906.2. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. Base flashing against a vertical sidewall shall be continuous or step flashing and shall be not less than 4 inches (102 mm) in height and 4 inches (102 mm) in width and shall direct water away from the vertical sidewall onto the roof or into the gutter. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. The installation of slate shingles shall comply with the provisions of this section. For the most common roof sheathing in our area, which is 1/2" nominal (7/16" actual) sheathing over trusses or rafters at 24" on center . Exception: Detached accessory structures not containing conditioned floor area. The ratio changes based on climate severity. Section R901 General R901.1 Scope The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. Flashing and counterflashing shall be made with sheet metal. For SI: 1 ounce per square foot = 0.305 kg/m. arrow_right. Modified bitumen membrane roofs shall have a design. If re-roofing over wood shingle, or wood shake roofs, additional code requirements may apply. Part III Building Planning and Construction, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T [RE] Solar-Ready ProvisionsDetached One- And Two-Family Dwellings and Townhouses, The provisions of this chapter shall govern the design, materials, construction and quality of, Roofs shall be covered with materials as set forth in Sections 904 and 905.
2018 International Residential Code (Irc) | Icc Digital Codes Roof Sheathing Ring Shank nails have been added to Table R602.3(1) Fastening Schedule with the designation RSRS-01 (2-3/8" x 0.113") as an option for roof sheathing attachment. Mineral-surfaced roll roofing shall not be applied on roof. 2018 International Residential Code (IRC) COPYRIGHT PREFACE EFFECTIVE USE OF THE INTERNATIONAL RESIDENTIAL CODE arrow_right CHAPTER 1 SCOPE AND ADMINISTRATION arrow_right CHAPTER 2 DEFINITIONS arrow_right CHAPTER 3 BUILDING PLANNING arrow_right CHAPTER 4 FOUNDATIONS arrow_right CHAPTER 5 FLOORS arrow_right CHAPTER 6 WALL CONSTRUCTION arrow_right 2018 IRC Simplified Wall Bracing Provisions 4 Objectives Upon completion, participants will be better able to: 1. Asphalt shingles shall be tested in accordance with ASTM D7158. Sprayed polyurethane foam roofs shall have a design. Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Wood shakes shall comply with the requirements of Table 905.8.5. Base and cap flashing shall be installed in accordance with manufacturer's instructions. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Section R803 Roof Sheathing R803.2 Wood Structural Panel Sheathing (Roof Online Note: This subsection covers plywood and OSB sheathing.